Should the alarm verification reset exceed 10 seconds, use the maximum initial start-up time. Ensure your FAAST device has the most up-to-date firmware. System Sensor web site at www.systemsensor.com. A. Some states do not allow the as identified by System Sensors compatibility chart. 1050 0 obj <>stream item 8 System Sensor 2W-B i3 Series 2-wire, Photoelectric Smoke Detector, 5.0 out of 5 stars based on 9 product ratings. View a list of all System Sensor locations worldwide. \kUb5{,P'Zwd**4C8X)z Using a 1000-1500 watt hair dryer, direct the heat toward either of the thermistors. This includes cleaning, maintenance or screen replacement. Make sure to observe polarity when wiring up your smoke detectors and you should connect an end-of-line resistor across the loop wires at the last 2W-B on your loop. Any advice/help would be greatly appreciated. Loop verification is provided by the EZ Walk loop test feature. 46 | Microsoft VP Marcus Fontoura on Architecting Azure, the "World's Computer" 0:00 / 0:00. Maximum Ripple Voltage: 30% of nominal (peak to peak), Alarm Current: 130mA max., limited by panel, Standby Current: 50 A max. away from the detector. Wired. Explore System Sensor like white papers, announcements, technical bulletins, case studies, and more. 2. This notification is not a safety issue, but low battery warnings should be addressed promptly to avoid potential problems with system operations which may arise. models must be used with compatible UL Listed panels only. Disable the zone or system undergoing maintenance 2009 System Sensor. List Price $134.00 Our Price $88.99 You Save $45.01 (34%) This chart contains the current list of . the incorporation of features compatible with drywall fasteners. Three-Year Limited Warranty INSTALLATION AND MAINTENANCE INSTRUCTIONS. The calculation points are in the horizontal and vertical planes in 5 degree increments per UL 1971. I am very happy with the purchase and while I only needed one I bought 2 to have one in reserve. Unlike traditional detection systems, Reflected Beam Smoke Detectors were designed for spacious rooms, open areas, and high ceilings; their innovative features make them popular choices for spaces like warehouses, atriums, arenas, and churches. 0 to 95% RH non-condensing To remove the detector from the base once it has been made tamper resistant, use a small screwdriver to depress the square tamper release tab, located on the skirt of the mounting base, and turn the detector counterclockwise. Additionally, to my comment below will the base of the unit likely fit the old base so I can just twist it into place after connecting the wires? PipeIQ guides users through the initial pipe layout and system configuration for a FAAST aspiration system. By subscribing I give my consent to receive AlarmGrid e-mails about Travis, with 4-wire smokes, you usually don't have to verify compatibility. The CLSS Tool Suite allows you to perform battery, voltage drop, and Db line loss calculations in a single desktop application. Developed and delivered by Honeywell industry experts, HBU training employs techniques and technologies to help your teams learn everything they can about our products. Wire the mounting base screw terminals per Figure 3a or Figure 3b, as 3. The detector will drop Power must be removed from the detector Insert a small screwdriver or allen wrench (0.18 max.) 32 to 100F (0 to 37.8C) 2. 2.0 inches increase or alter the obligations or limitations of this Warranty. Max. All models incorporate a state-of-the-art optical sensing chamber and an advanced microprocessor. System Sensor makes no representations whatsoever with regard to the quality or function of AFMGs EASE Evac software. A copy of this list is available from System Sensor upon request. However, there is no guarantee that interference will not occur in a particular installation. The System Sensor 2W-B is a 2-wire smoke detector and a member of System Sensor's i3 Series of photoelectric smoke detectors. No agent, representative, dealer, or employee of the Company has the authority to Please read thoroughly System Sensor manual A05-1003, Applications Guide General Technical details Weight & dimensions Operational conditions Power Power source AC/DC show more Frequently Asked Questions Can't find the answer to your question in the manual? indicate a need for cleaning, replacement, or a fr eeze condition (2WT -B only) at the control panel or module. NOTE: If, during power-up, the detector determines there is excessive electrical noise in the system such as those caused by improper grounding of the system or the conduit, both LEDs will blink for up to 4 minutes before displaying detector status (see Table 2). ABOUT US Updates prevent a system from responding properly in the event of a fire. Applications Guide for System Smoke Detectors, which provides detailed information on detector spacing, placement, zoning, wiring, and special applications. System Sensor BK-2WB Photoelectric i3 Series Smoke Detector, 2-Wire, White Brand: System Sensor ADI #:BK-2WB Model #: 2W-B Name: System Sensor BK-2WB Photoelectric i3 Series Smoke Detector, 2-Wire, White Plug-in detector line, mounting base included Large wire entry port In-line terminals with SEMS screws Product Overview Installation ease. I have an old System Sensor 2 wire photoelectric smoke alarm (hardwired) that is about 17 years old and has finally gone out - trying to figure out if this particular unit will work seamlessly as a replacement for my existing alarm - there is a connection to the back of the alarm and wonder if I can just hook up the new alarm the same away the old alarm is connected and have it work? 4. The conductors used to connect smoke Series 2W-MOD module (refer to installation manual D500-46-00), the 2W-B and 2WT-B are capable of generating a "maintenance. FREE delivery Sat, Feb 11. KingOfTheP4s 3 yr. ago Best thing to do in this case would be to call the company of your choice, such as EST, and ask a sales representative to give you a list of MRI-safe devices. 4.8 out of 5 stars based on 20 product ratings, 4.8 out of 5 stars based on 166 product ratings, 4.9 out of 5 stars based on 174 product ratings, 4.8 out of 5 stars based on 175 product ratings, 4.8 out of 5 stars based on 190 product ratings, 5.0 out of 5 stars based on 1 product rating. When the detector is in the, alarm mode, the red LED latches on. (135F) thermal detector and are also capable of sensing a freeze condition if Hold the heat source about 12 inches from the detector to avoid damage FREE delivery Mar 8 - 10. F :9M9yB*]}8s5CC)^.+Jnz>>;?88^]~xxfntMr}->rz_Sxu%fYz,b,v%-]r9Yfl){fy\1W+ye"3#r9c/DfO+"!a4{=ff^,. unreasonable use, modifications, or alterations occurring after the date of manufacture. System Sensor's AV notification devices are one of the most versatile, easy to install, and cohesive audible visual (AV) notification appliances in the industry. Blink 5 sec When the alarm goes off, both keypads seem like they short out for a second (the display panel goes blank the ready and arm lights flash, and it makes a weird beeping noise) then starts the alarm tone at the keypads only. It would be hard to rate this product at one star unless it was somehow responsible for an unreported house fire. ld house alarm system. System Sensors AV notification devices are the most versatile, easy to install, and cohesive line of audible visual (AV) notification appliances in the industry. Operating Temperature Range: . In a freeze, trouble condition, the red LED will blink once every 10 seconds, To measure the detector's sensitivity, the i, RDR Infrared Sensitivity Reader tool (see Figure 4) should be, Models 2W-B and 2WT-B also include an output that allows an. Figure 4: Recessed Test Switch Opening and SENS-RDR Position Enter your email address and check your inbox. particles from entering the detector. NFPA 72 requirements. tor. Each zone provides enough stand by current (2ma) to power up to sixteen smoke detectors. ANSI/UL 1971 does not provide ratings for each angle based on actual test results.". For applicable. The System Sensor 2W-B smoke detector has a sensing chamber that that will become dirty with dust over time. They also answer your questions from the comfort of home or the office. Consult the dealer or an experienced radio/TV technician for help. To stay in the know on upcoming news and announcements, subscribe. Z@~P]%*?p S_iVN$rtE;[\SmgisL^aOTYVE \xOQc_m1eN"hB~n5#{f-!tEn -:)D#bBc7yo0x&i9Su%t wa+"i Blink 10 sec I was planning on installing about 11 of these on a vista 21ip panel, what is the power draw I should account for when planning against the 650 mA allowance for the panel? Alarm Contact Ratings: 130 It can connect with a Honeywell VISTA System at Zone 1. Turn on: 1. Developed and delivered by Honeywell industry experts, HBU training employs techniques and technologies to help your teams learn everything they can about our products. The LED indication must not In wet or excessively humid areas, or next to bathrooms with showers. Fill out our feedback form! Vacuum or use canned air to remove any dust or particles that are present on both chamber halves. Press When connected to the 2W-MOD2 loop test/ maintenance module or an i3 Ready (TM) panel, 2 wire i3 detectors can generate a remote maintenance signal when in a maintenance or freeze trouble condition. Do NOT Install Detectors in the Following Areas: In or near areas where particles of combustion are normally present such as kitchens; in garages (vehicle exhaust); near furnaces, hot water heaters, or gas space heaters. Table 1: Detector LED Modes For two-wire models 2W-B and 2WT-B, connect detectors only to compatible alarm control panels as identified by System Sensor's compatibility chart. alarm verification. 2-Wire i3 Detector Wired in Style D Configuration: B. An overview of latest updates, essential resources, and webinars. (See Figure 4.). BY THE WORD PAINT, PUSH RECESSED No Contract Alarm Monitoring starting at $10 a month! System Sensor shall have no liability. Consult the list to locate a control module for your specific fire alarm system. Max. $5899 $69.99. Do NOT Install Detectors in the Following Areas: This chart contains the current list of detectors and UL Listed compatible control units. Alarm Type. To view our listings, please visit one of the following sites. However, they may not completely prevent airborne dust Upload manuals that we do not have and get. sensitivity back to the factory setting when it becomes more sensitive due to Band Color. If the detector is within the listed sensitivity limits, the detectors red To a 4-inch square box with a plaster ring, or Initial LED Status Indication. may also have other rights which vary from state to state. Before Installing It should be straightforward if you do not need to wire the back plate. 1-800-SENSOR2, FAX: 630-377-6495 15 130 heads and bases are clearly identified as either 2-wire or 4-wire. If the detector is in need of maintenance, because its sensitivity has shifted outside the listed limits, the red, LED blinks once every five seconds. system or the conduit, both LEDs will blink for up to 4 minutes before displaying detector status (see Table 2). best system performance, all wiring should be installed in separate grounded Diameter (including base): Do you see that white unit anywhere in or near your 20P alarm panel? 3825 Ohio Avenue, St. Charles, Illinois 60174 Latching Alarm: Reset by momentary power interruption NOTE: Style. 2. before performing maintenance of any kind. After some recent electrical work (new AC unit in the attic) the vista 20p shows fire trouble, and occasionally sets off the alarm. Please send an email to support@alarmgrid.com referring to this inquiry to better assist you with your 20P. The 2W-B smoke detector works with most Honeywell alarm control panels including the VISTA-20P and VISTA-21iP as System Sensor is a subsidiary of Honeywell. To measure the detectors sensitivity, the i3 Series Model SENS-RDR Infrared All wiring must be installed in compliance with the National Electrical Code, applicable state and local codes, and any special requirements of the local Authority Having Jurisdiction. I recommend powering down the system and placing your system on test mode if monitored before swapping in the new smoke. The System Sensor 2W-B is a 2-wire smoke detector and a member of System Sensors i3 Series of photoelectric smoke detectors. way to insure proper operation of 2-wire i3 smoke detectors (2W-B, 2WT-B, Alarm Reset Time: Installation of the 2W -B, 2WT -B, 4W -B, and 4WT -B detectors is simplified . Our hardwired CO detectors with RealTest use electrochemical sensors to measure carbon monoxide levels and alert residents with a flashing Temp-4 signal alarm. 2WTA-B, or 2WTR-B) on Style D IDCs is to use a 2W-MOD2 module. All i3 Series detectors are designed to provide open area protection. against extraneous electrical interference. MOD2 module (refer to installation manual D5 00-46-00), the 2W -B and 2WT -B. are capable of gener ating a "maintenance needed" signal. This includes cleaning, maintenance or screen replacement. The System Sensor 2W-B is a 2-wire smoke detector and a member of System Sensors i3 Series of photoelectric smoke detectors. Remove power from alarm control unit or initiating device circuits before installing detectors. Users of this calculator are solely responsible for their own selection and use of products based upon information contained in this calculator and any calculations from this calculator. for use with i3 Series compatible control panels or the i3 Series 2W-MOD module only. in the Style D initiating device circuit (IDC) configuration requires the use Low-Profile Plug-in Smoke/Heat Detector 800 Series System Sensor's 800 series detectors are 2-wire conventional profile plug-in detectors aimed to meet the performance criteria designated by UL. They also answer your questions from the comfort of home or the office. indicate a need for cleaning, replacement, or a freeze condition (2WT-B only) Table 2: Power-up Sequence for LED Status Indication* Each i3 Series detector is supplied with a mounting base that can be mounted: 2.To a 312-inch or 4-inch octagonal box, or, 3.To a 4-inch square box with a plaster ring, or. The LED indication must not be used in lieu of the tests specified under Testing. and service during the three year period commencing with the date of manufacture. - 2W- B More results Similar Description - 2W-B More results list is available from System Sensor upon request. Place detector on the base and rotate clockwise. The i3 Series detectors include a tamper-resistant feature that prevents removal System Sensors AV notification devices are the most versatile, easy to install, and cohesive line of audible visual (AV) notification appliances in the industry. In dusty, dirty, or insect-infested areas. SMOKE Or should i plan on just running the wire directly out of the drywall? such as kitchens; in garages (vehicle exhaust); near furnaces, hot water i3 series (4 pages), I3 series. I am not of the exact model number of the existing 2-wire smoke detector so I cannot say for sure if the back plates are the same. Multi-voltage conventional relays are used for high-current switching applications, such as fan and damper assembly control, door control, air handling unit controls, and other building system interfaces. To measure the detectors sensitivity, the i3 Series Model SENSRDR Infrared Sensitivity Reader tool (see Figure 4) should be used. 6. endstream endobj 473 0 obj <> endobj 474 0 obj <> endobj 475 0 obj <> endobj 476 0 obj <> endobj 477 0 obj <> endobj 478 0 obj <>stream We're here to provide technical support for System Sensor products and service. for System Smoke Detectors, which provides detailed information on detector NOTE: Before performing maintenance on the detector, notify the proper authorities that maintenance is being performed and the system will be temporarily out of service. The System Sensor 2WT-B is a 2-wire smoke and heat detector. The mounting base installation is further simplified by the incorporation of features compatible with drywall fasteners. be used in lieu of the tests specified under Testing. 3. RA400Z Remote Annunciator to be connected. to the plastic. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to the listed limits, the red LED blinks once every five seconds. I have a DSC alarm system that my current System Sensors are connected to and would I need to do anything special when I replace the old with the new other then reset the system? The i3 Series 2W-B uses drift compensation technology and smoothing algorithms which prevent the smoke detector from becoming too sensitive as dust accumulates. Thank you for the response @disqus_YuNiL6S1Rn:disqus. When mounting the i3 Series, ensure that the head is mounted to the correct base. Product specifications subject to change without notice. applicable state and local codes, and any special requirements of the local Car & Truck Safety & Security Accessories. The LED indication must not, be used in lieu of the tests specified under Testing. Start-up Time: When used with an i3 Series compatible control panel or the i3 Series 2W-MOD module (refer to installation manual D500-46-00), the 2W-B and 2WT-B are capable of generating a maintenance needed signal. detector to finish the power-up cycle (see Table 2). Heat Sensor (Model 2WT-B and 4WT-B): 4-Wire Smoke Detector with 135F Fixed Heat Sensor, 2-Wire Smoke Detector with Fixed Heat Sensor, System Sensor 2W-B, 2WT-B, 4W-B & 4WT-B - Installation Guide. 1000 0 obj <> endobj Explore System Sensor products including: AV Notification, Beam Smoke detection, CO detection, HVAC Smoke detection, spot smoke detection, relays, & modules. System Sensor products are designed and manufactured to meet or exceed various product safety and certification requirements. LED should light within five seconds. In or near areas where particles of combustion are normally present Test Switch Turn it on by pushing the button of the wired remote. OVAL AREA OR AT THE Therefore, the only Please refer to insert for the Limitations of Fire Alarm Systems I will say that it came packaged correctly and it functions as designed, would buy again. 7.7K views 1 year ago DSC Power Series Neo Installation Series Two wire type smoke detectors are arguably the simplest smokes to use with an alarm system, yet we still get installation questions. An opening for the recessed test switch is located on the detector housing (See Figure 4). 32 Degrees to 120 Degrees F. Battery Backup. General CLSS Tool Suite Discontinued Product Finder AV Audio Samples: AV Tones Calculator: AV Strobe Coverage Calculator: Voltage Drop Calculator: Sound Pressure Loss Detectors must be tested after installation and following maintenance. Notify the proper authorities that the system is in operation. into the test $59.99. w responsible for an unreported house fire. 135F (57.2C) Increase the separation between the equipment and receiver. COVER. The 2W-B smoke detector is not the typical conventional detector. For two-wire models 2W-B and 2WT-B, connect detectors only to compatible alarm control panels as identified by System Sensor's compatibility chart. Consult NFPA 72, the local Authority Having Jurisdiction (AHJ), and/or applicable codes for specific information regarding the spacing and placement IMPORTANT: This detector must be tested and maintained regularly following NFPA 72 requirements. Remove the detector cover by turning counterclockwise. Solid, After an initial power-up delay, the red and green LEDs will blink synchronously once every ten seconds. For best system performance, all wiring should be installed in separate grounded conduit; do not mix fire alarm system wiring in the same conduit as any other electrical wiring. item 3 System Sensor 2W-B 2WB i3 Series 2-wire Photoelectric Smoke Detector System Sensor 2W-B 2WB i3 Series 2-wire Photoelectric Smoke Detector. In wet or excessively humid areas, or next to bathrooms with showers. photoelectric smoke detector (4 pages), Intrinsically-safe plug-in intelligent photoelectronic smoke detector (6 pages), Single-ended reflected type projected beam smoke detector (19 pages), Single-ended reflected type projected beam smoke detector (14 pages), Air duct smoke detector with extended air speed range (8 pages), Photoelectronic smoke detector with fixed heat and integral temp-3 sounder (4 pages), Reflected type projected beam smoke detector (6 pages), Combination carbon item 2 System Sensor 2W-B I3 Series 2-Wire Photoelectric Smoke Detector, item 3 NEW System Sensor 2W-B 2WB i3 Series 2-Wire Photoelectric Smoke Detector Fire, item 4 System Sensor 2W-B i3 Series 2-wire, Photoelectric Smoke Detector, item 5 NEW System Sensor 2W-B 2WB i3 Series 2-Wire Photoelectric Smoke Detector Fire. NOTE: Before testing, notify the proper authorities that maintenance is being System Sensor 2W-B Photoelectric i3 Smoke Detector, 2-Wire In Stock Other products from System Sensor System Sensor P4W-P Horn Strobe, White, Wall Mount, Four-Wire System Sensor PC2W Horn Strobe, White, Ceiling Mount, Two-Wire, FIRE Lettering System Sensor B210LP Detector Base, Plug-In Start-up Capacitance: or exclusion may not apply to you. It should connect the same exact way. Ready to learn more? To calculate performance-based strobe coverage, the inverse square law is used to calculate the illumination at each of the angles in the horizontal and vertical planes per ANSI/UL 1971, Standard for Signaling Devices for the Hearing Impaired, and the effect of polar distribution is included using the minimum percentages in ANSI/UL 1971 or actual test results recorded by the Listing organization. Dust covers are an effective way to limit the entry of dust into the smoke detector sensing chamber. System Sensors intelligent and conventional modules are designed to help you meet a wide range of application requirements. A copy of this list is available from System Sensor upon request. 2. B401B / B406B / B110LP / B116LP A 120 System Sensor 2800 A Photo N/A N/A 120 System Sensor 2800TH A Photo / Therm. This system was used with Cox before, so no telling what all they did to it. mounted: Proper wire gauges should be used. Two LEDs on the detector provide a local visual indication of the, After an initial power-up delay, the red and green LEDs will blink, synchronously once every ten seconds. Ep. System Sensor 2W-B Product Specifications: System Sensor 2W-B Product Compatibility: Plug-in detector line, mounting base included, Mounts to octagonal and single-gang back boxes, 4-square back boxes, or direct to ceiling, Drift compensation and smoothing algorithms. breach of this or any other Warranty, expressed or implied whatsoever, even if the loss Please include a Smoke Alarm. Any 2-wire i3 smoke detector (2W-B, 2WT-B, 2WTA-B, or 2WTRB) wired Its simple, step-by-step process makes it easy for users to configure panels and circuits from a variety of devices. any latin characters (a-z, A-Z) any numbers (0-9) special characters ("-", "_" and ". Should it become necessary, the screen/sensing chamber is field replaceable. 0.3 sec the temperature is below 41F. optional Model RA400Z Remote Annunciator to be connected. $156.00. 1015 0 obj <>/Encrypt 1001 0 R/Filter/FlateDecode/ID[<493E40FFCF1D3F747B74E48D03207C10>]/Index[1000 51]/Info 999 0 R/Length 93/Prev 198552/Root 1002 0 R/Size 1051/Type/XRef/W[1 3 1]>>stream on the screen/sensing chamber with the arrow on the housing. z7$m9ymnsx.}]{~{^^}ltW? WIRING DIAGRAMS FIGURE 3A: WIRING DIAGRAM, 2W-B AND 2WT-B 2 . Improper connections can Podcast; Latest Figure 1: Mounting of Detector. In a freeze trouble condition, the red LED will blink once every 10 seconds (refer to Table 1). The mounting base installation is Similar Part No. accept any interference received, including interference that may cause undesired operation. Fill out our feedback form! The heads and bases are clearly identified as either 2-wire or 4-wire. visual status indication at each detector. Models 2WT-B and 4WT-B also feature a restorable, built-in, fixed temperature System Sensor 2W-B Product Description: The System Sensor 2W-B is a i3-Series conventional, two-wire, photoelectric smoke detector.
Ecnl Regional League Championships, Articles S